MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 760

Advertising
background image

Index - 10

[R]

READY (Explanation of positioning terms)

.......................................................... Appendix-86

Real-time AUTO tuning (Explanation of positioning

terms)................................................ Appendix-86

Reference axis............................................... 9-22

Reference axis speed ................................... 5-33

Reference axis speed (Explanation of positioning

terms)................................................ Appendix-86

Regeneration brake option (Explanation of

positioning terms) ............................. Appendix-86

Relatively safe stop ....................................... 6-42

Remote I/O station .......................................... 2-5

Repeated start (FOR condition).................. 10-14

Repeated start (FOR loop).......................... 10-13

Resolver (Explanation of positioning terms)

.......................................................... Appendix-86

Restart command ( Cd.6 ) ......................... 5-112

Restart operation........................................... 6-39

Restart program ............................................ 6-39

RLS signal (Explanation of positioning terms)

.......................................................... Appendix-86

Rotary table ...................................... Appendix-86

Rotation direction setting ( Pr.6 )................ 5-22

[S]

S-pattern acceleration/deceleration

.......................................................... Appendix-86

SERIAL No. ..............................1-22, Appendix-2

Servo amplifier (Explanation of positioning terms)

.......................................................... Appendix-86

Servo lock (Explanation of positioning terms)

.......................................................... Appendix-87

Servo ON (Explanation of positioning terms)

.......................................................... Appendix-87

Servomotor (Explanation of positioning terms)

.......................................................... Appendix-87

Setting data ..................................................... 5-2

Setting for the movement amount after near-point

dog ON (

Pr.50

).......................................... 5-54

Setting items for block start data .................. 5-10
Setting items for condition data .................... 5-11

Setting items for OPR parameters

......................................................................... 5-6

Setting items for positioning data.................... 5-7

Setting items for positioning parameters ........ 5-4

Setting the positioning data ...........................9-22

Setting the torque limit function ...................12-25

Setting unit (Explanation of positioning terms)

.......................................................... Appendix-87

SFC (Explanation of positioning terms)

.......................................................... Appendix-87

Shape (

Da.11

) ............................................5-77

Signal layout of connector .............................3-19

Signal name ...................................................3-14
Signals

• Axis stop signal ........................................3-16

• BUSY signal.............................................3-15

• Error detection signal...............................3-15

• JOG start signal .......................................3-16

• M code ON signal ....................................3-15

• PLC READY signal................................. 3-16

• Positioning complete signal.....................3-15

• Positioning start signal.............................3-16

• QD75 READY signal ...............................3-15

• Start complete signal ...............................3-15

• Synchronization flag signal......................3-15

Simultaneous start .......................................10-12

Simultaneous starting axis start data No. (Axis 1

start data No.) (

Cd.30

)..............................5-128

Simultaneous starting axis start data No. (Axis 2

start data No.)(

Cd.31

)...............................5-128

Simultaneous starting axis start data No. (Axis 3

start data No.)(

Cd.32

)...............................5-128

Simultaneous starting axis start data No. (Axis 4

start data No.)(

Cd.33

)...............................5-128

Skip command (

Cd.37

).............................5-130

Skip function.................................................12-59

Skip function (Explanation of positioning terms)

.......................................................... Appendix-87

Skip operation program .................................6-14

Slave axis (Explanation of positioning terms)

.......................................................... Appendix-87

Slot ...................................................................2-5

Software stroke limit lower limit value (

Pr.13

)

........................................................................5-28

Software stroke limit selection (

Pr.14

).......5-28

Software stroke limit upper limit value (

Pr.12

)

........................................................................5-28

Software stroke limit valid/invalid setting (

Pr.15

)

........................................................................5-28

Advertising