Melsec-q, 3] setting the speed limit function, Remark – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 498

Advertising
background image

12 - 22

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[2] Precautions during control

If any axis exceeds " Pr.8 Speed limit value" during 2- to 4-axis speed control,

the axis in excess of the speed limit value is controlled at the speed limit value.

The speeds of the other axes interpolated are suppressed depending on their

command speed ratios.

If the reference axis exceeds " Pr.8 Speed limit value" during 2- to 4-axis linear

interpolation control, 2- to 4-axis fixed-feed control or 2-axis circular interpolation

control, the reference axis is controlled at the speed limit value (The speed limit

does not function on the interpolation axis side.)

[3] Setting the speed limit function

To use the "speed limit function", set the "speed limit value" in the parameters

shown in the following table, and write them to the QD75.

The set details are validated after they are written to the QD75.

Setting item

Setting

value

Setting details

Factory-set
initial value

Pr.8

Speed limit value

Set the speed limit value (max. speed during control).

200000

Pr.31

JOG speed limit
value

Set the speed limit value during JOG operation (max.

speed during control). (Note that "

Pr.31

JOG speed

limit value" shall be less than or equal to "

Pr.8

Speed limit value".)

20000

Refer to Section 5.2 "List of parameters" for setting details.

REMARK

Parameters are set for each axis.

It is recommended that the parameters be set whenever possible with GX

Configurator-QP. Execution by sequence program uses many sequence programs

and devices. The execution becomes complicated, and the scan times will

increase.