Melsec-q, 15 troubleshooting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 619

Advertising
background image

15 - 15

MELSEC-Q

15 TROUBLESHOOTING

Related buffer memory

address

Axis 1 Axis 2 Axis 3 Axis 4

Set range

(Setting with sequence program)

Remedy

New current value

1506
1507

1606
1607

1706
1707

1806
1807

Software stroke limit

upper limit

18
19

168
169

318
319

468
469

Software stroke limit

lower limit

20
21

170
171

320
321

470
471

<New current value>

<Software stroke upper and lower

limits>

• [mm] [inch] [pulse]

–2147483648 to 2147483647

• [degree]

0 to 35999999

At start: Bring the current feed value into the software

stroke limit using the manual control
operation.
(Refer to Chapter 11)
Correct the positioning address (Also check
the arc address in circular interpolation with
sub points designated).

New current value:

Bring the new current value into the software
stroke limit. (Refer to Section 9.2.19)

During operation:

Correct the positioning address.
(For the positioning and arc addresses, refer
to

Da.6

and

Da.7

in Section 5.3.)

1506
1507

1606
1607

1706
1707

1806
1807

<New current value>

[degree] 0 to 35999999

Bring the new current value into the setting range.
(Refer to Section 9.2.19)

• Do not designate a current value changing using the

positioning data following the continuous path control.

• Do not designate a "current value changing" using the

positioning data following the continuous path control.
(Refer to Section 9.2.19)

Refer to Section 5.3

"List of positioning data"

<Control system>

01

H

to 1E

H

, 80

H

to 84

H

• 03

H

, 0C

H

, 17

H

, 1C

H

:

1 to 4 axis fixed-feed control

• 04

H

, 05

H

, 13

H

, 14

H

, 18

H

, 19

H

, 1D

H

,

1E

H

:

1 to 4 axis speed control

• 81

H

: current value changing

• Speed-position switching control:

06

H

, 07

H

• Position-speed switching control:

08

H

, 09

H

<Operation pattern> 00, 01, 11

• 01: Continuous positioning control

• 11: Continuous path control

• Do not designate a speed control, fixed-feed, speed-

position switching control, and position-speed
switching control using the positioning data following
the continuous path control data.

• Do not carry out the fixed-feed, speed control, speed-

position switching control, and position-speed
switching control using the continuous path control
operation pattern.

• Do not carry out the speed control and position-speed

switching control using the continuous path control
operation pattern.
(Refer to Chapter 9)