Control data

Item

A1SD75

QD75

Clock data setting (hour)

Cd.1

Clock data setting (minute, second)

Cd.2

Clock data writing

Cd.3

Target axis

Cd.4

Positioning data No.

Cd.5

Write pattern

Cd.6

Read/write request

Cd.7

Read/write positioning data I/F

Cd.8

Flash ROM write request

Cd.9

Cd.1

Parameter initialization request

Cd.10

Cd.2

Positioning start No.

Cd.11

Cd.3

Axis error reset

Cd.12

Cd.5

Restart command

Cd.13

Cd.6

M code OFF request

Cd.14

Cd.7

New current value

Cd.15

Cd.9

New speed value

Cd.16

Cd.14

Speed change request

Cd.17

Cd.15

Positioning operation speed override

Cd.18

Cd.13

JOG speed

Cd.19

Cd.17

Inching movement amount

Cd.16

Speed-position switching enable flag

Cd.20

Cd.24

Speed-position switching control movement amount change register

Cd.21

Cd.23

Position-speed switching enable flag

Cd.26

Position-speed switching control speed change register

Cd.25

Target position change request flag

Cd.29

Target position change value (new address)

Cd.27

Target position change value (new speed)

Cd.28

ABS direction in degrees

Cd.40

Manual pulse generator enable flag

Cd.22

Cd.21

Manual pulse generator 1 pulse input magnification

Cd.23

Cd.20

OPR request flag OFF request

Cd.24

Cd.19

External start valid (QD75: Cd. 8 External command valid)

Cd.25

Cd.8