5 - 123

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Setting value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Set with a decimal.

Setting
value

K

OPR request flag OFF request
1: Turns the "OPR request flag"
from ON to OFF.

The QD75 resets the value to "0" automatically when the OPR
request flag is turned OFF.
(This indicates the completion of OPR request flag OFF request.)

1

0

1521

1621

1721

1821

Set with a decimal.

Setting value

K

Manul pulse generator
1 pulse input
magnification

1 to 100

1

1522
1523

1622
1623

1722
1723

1822
1823

Set with a decimal.

Setting value

Manual pulse generator enable flag
0: Disable manual pulse generator operation.
1: Enable manual pulse generator operation.

K

0

1524

1624

1724

1824

Set with a decimal.

Setting value

K

Torque change value

1 to Pr.17 Torque limit setting value

0

1525

1625

1725

1825