Melsec-q, 15 troubleshooting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 632

Advertising
background image

15 - 28

MELSEC-Q

15 TROUBLESHOOTING

Classification

of errors

Error
code

Error name

Error

Operation status at error occurrence

954

Deceleration time 2
setting error

The set range of the detailed
parameter 2 "Deceleration time 2" is
outside the setting range.

955

Deceleration time 3
setting error

The set range of the detailed
parameter 2 "Deceleration time 3" is
outside the setting range.

956

JOG speed limit
value error

• The set range of the detailed

parameter 2 "JOG speed limit value"
is outside the setting range.

• The set range of the detailed

parameter 2 "JOG speed limit value"
exceeds the speed limit.

957

JOG acceleration
time selection setting
error

The set range of the detailed parameter
2 "JOG acceleration time selection
setting" is outside the setting range.

958

JOG deceleration
time selection setting
error

The set range of the detailed parameter
2 "JOG deceleration time selection
setting" is outside the setting range.

959

Acceleration/
deceleration process
selection setting
error

The set range of the detailed
parameter 2 "Acceleration/deceleration
process selection setting" is outside
the setting range.

960

S-pattern ratio
setting error

The set range of the detailed
parameter 2 "S-pattern ratio" is outside
the setting range.

961

Illegal sudden stop
deceleration time

The set range of the detailed
parameter 2 "Sudden stop deceleration
time" is outside the setting range.

962

Stop group 1 sudden
stop selection error

The set range of the detailed
parameter 2 "Stop group 1 sudden
stop selection" is outside the setting
range.

963

Stop group 2 sudden
stop selection error

The set range of the detailed
parameter 2 "Stop group 2 sudden
stop selection" is outside the setting
range.

964

Stop group 3 sudden
stop selection error

The set range of the detailed
parameter 2 "Stop group 3 sudden
stop selection" is outside the setting
range.

966

Outside allowance
circular interpolation
error width

The set range of the detailed
parameter 2 "Allowance circular
interpolation error width" is outside the
setting range.

967

External command
function selection
error

The set range of the detailed
parameter 2 "External command
function selection" is outside the
setting range.

At start: The system will not

operate.

During operation:

The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2
Sudden stop selection
(stop group 3).

(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)

Parameter

980

OPR method error

The set range of the OPR basic
parameter "OPR method" is outside
the setting range.

The QD75 READY signal (X0) is not
turned ON.