Melsec-q, 5 data used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 218

Advertising
background image

5 - 130

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting item

Setting details

Cd.36

Step start information

During a step operation, this data item determines whether the operation is
continued or restarted.

Cd.37

Skip command

To skip the current positioning operation, set "1" in this data item.

Cd.38

Teaching data selection

This data item specifies the teaching result write destination.

Cd.39

Teaching positioning data No.

This data item specifies data to be produced by teaching.

If a value between 1 and 600 is set, a teaching operation is done.

The value is cleared to "0" when the QD75 is initialized, when a teaching
operation completes, and when a illegal value (601 or higher) is entered.

Cd.40

ABS direction in degrees

This data item specifies the ABS moving direction carrying out the position control
when "degree" is selected as the unit.

Advertising