6 - 43

MELSEC-Q

6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL

[2] Types of stop processes

The operation can be stopped with deceleration stop, sudden stop or immediate

stop.

(1) Deceleration stop 1

The operation stops with "deceleration time 0 to 3" (

Pr.10

,

Pr.28

,

Pr.29

,

Pr.30

).

Which time from "deceleration time 0 to 3" to use for control is set in positioning

data ( Da.4 ).

(2) Sudden stop

The operation stops with "

Pr.36

Sudden stop deceleration time".

(3) Immediate stop

The operation does not decelerate.
The QD75 immediately stops the pulse output, but the operation will coast for
the droop pulses accumulated in the drive unit's deviation counter.

Actual deceleration time

Set deceleration time

Positioning speed

Actual sudden stop
deceleration time

Pr. 36 Sudden stop
deceleration time

Coast for the droop pulses accumulated
in the drive unit's deviation counter.

Positioning speed

Positioning speed

Fig. 6.15 Types of stop processes

REMARK

1 "Deceleration stop" and "sudden stop" are selected with the details parameter 2

"stop group 1 to 3 sudden stop selection". (The default setting is "deceleration

stop".

)