Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 400

Advertising
background image

9 - 100

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Operation timing and processing time during position-speed switching

control

Positioning start signal
[Y10,Y11,Y12,Y13]

BUSY signal [XC,XD,XE,XF]

M code ON signal

[X4,X5,X6,X7](WITH mode)

Standing by

In position control

Standing by

Axis operation status

M code OFF request

Start complete signal [X10,X11,X12,X13]

Output pulse to an external source

(PULSE)

Positioning operation

M code ON signal [X4,X5,X6,X7]

(AFTER mode)

M code OFF request

t1

t2

t3

t4

t2

Positioning complete signal
[X14,X15,X16,X17]

In speed control

Position

control

Speed

control

External position-speed switching

command

t6

Position control carried out until position-speed switching
signal turns ON.

Speed control command speed is from the input position of
the external position-speed switching signal.

Md.26

Position-speed switching

control speed change register

Cd.25

Cd. 7

Cd. 7

Status: b4

OPR complete flag

Md.31

Stop signal

[STOP]

Fig. 9.19 Operation timing and processing time during position-speed switching control

Normal timing time Unit: ms

t1

t2

t3

t4

t5

t6

1.0 to 1.4

0 to 1.8

0 to 1.8

2.7 to 4.4

-

1.0

The t1 timing time could be delayed by the operation state of other axes.

Advertising