Melsec-q, 12 control sub functions [4] teaching procedure – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 548

Advertising
background image

12 - 72

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[4] Teaching procedure

The following shows the procedure for a teaching operation.
(1) When teaching to the "

Da.6

Positioning address/movement amount"

(Teaching example on axis 1)

Start

Perform machine OPR on axis 1

Move the workpiece to the
target position using a manual
operation.

Set Writes the current feed value
to Da.6 Positioning address/
movement amount in teaching
data selection.

Set the positioning data No. for
which the teaching will be carried
out.

End teaching?

Turn OFF the PLC READY
signal [Y0].

Carry out a writing request to
the flash ROM.

End

Confirm completion of writing.

Using a JOG operation, inching operation, or manual pulse generator.

Set the positioning data No. in buffer memory address [1549].

Set 0 in buffer memory address [1548].

Confirm completion of the
teaching.

Confirm 0 in buffer memory address [1549].

Set 1 in buffer memory address [1900].

Confirm 0 in buffer memory address [1900].

NO

YES

Advertising