Melsec-q, 5 data used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 214

Advertising
background image

5 - 126

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting item

Setting details

Cd.26

Position-speed switching
control enable flag

Set whether the external control signal (external command signal [CHG]: "speed-
position, position-speed switching request" is selected) is enabled or not.

When changing the target position during a positioning operation, use this data
item to specify a new positioning address.

Set a value within the following range:

Pr.1

mm

(

×

10

-1

µm)

inch

(

×

10

-5

inch)

degree

(

×

10

-5

degree)

pulse

(pulse)

ABS

-2147483648

to

+2147483647

-2147483648

to

+2147483647

0 to 35999999

-2147483648

to

+2147483647

INC

-2147483648

to

+2147483647

-2147483648

to

+2147483647

-2147483648

to

+2147483647

-2147483648

to

+2147483647

Cd.27

Target position change value
(New address)

When changing the target position during a positioning operation, use this data
item to specify a new speed.

The speed will not change if "0" is set.

Set a value within the following range:

Pr.1

mm

(

×

10

-2

mm/min)

inch

(

×

10

-3

inch/min)

degree

(

×

10

-3

degree/min)

pulse

(pulse/s)

Setting range

0 to

2000000000

0 to

2000000000

0 to

2000000000

0 to 1000000

Cd.28

Target position change value
(New speed)

Cd.29

Target position change
request flag

Requests a change in the target position during a positioning operation.