Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 337

Advertising
background image

9 - 37

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Restrictions

An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.

If the movement amount of each axis exceeds "1073741824 (=2

30

)" when "0:

Composite speed" is set in " Pr.20 Interpolation speed designation method"
... The "Outside linear movement amount range error (error code: 504)" occurs

at a positioning start.

(The maximum movement amount that can be set in " Da.6 Positioning

address/movement amount" is "1073741824 (=2

30

)".)

Positioning data setting example

[Reference axis is designated as axis 1.]
The following table shows setting examples when "3-axis linear interpolation
control (INC linear 3)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2 and axis 3.)

Axis

Setting item

Axis 1

(reference

axis) setting

example

Axis 2

(interpolation

axis) setting

example

Axis 3

(interpolation

axis) setting

example

Setting details

Da.1 Operation pattern

Positioning

complete

Set "Positioning complete" assuming the next
positioning data will not be executed.

Da.2 Control system

INC linear 3

Set incremental system 3-axis linear
interpolation control.

Da.3

Acceleration time
No.

1

Designate the value set in " Pr.25
Acceleration time 1" as the acceleration time
at start.

Da.4

Deceleration time
No.

0

Designate the value set in " Pr.10
Deceleration time 0" as the deceleration time
at deceleration.

Da.5

Axis to be
interpolated

Setting not required (setting value will be
ignored).

When axis 1 is used as a reference axis, the
interpolation axes are axes 2 and 3.

Da.6

Positioning address/
movement amount

10000.0

µ

m 5000.0

µ

m

6000.0

µ

m

Set the movement amount. (Assuming "mm"

is set in "

Pr.1

Unit setting".)

Da.7 Arc address

Setting not required (setting value will be
ignored).

Da.8 Command speed

6000.00
mm/min

Set the speed during movement.

Da.9 Dwell time

500ms

Set the time the machine dwells after the
positioning stop (pulse output stop) to the
output of the positioning complete signal.

A

x

is 1 Positioning data N

o

. 1

Da.10 M code

10

Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.