Melsec-q, 5 data used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 153

Advertising
background image

5 - 65

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

When " Pr.1 Unit Setting" is "pulse"

The table below lists the control systems that require the setting of the positioning
address or movement amount and the associated setting ranges.
(With any control system excluded from the table below, neither the positioning
address nor the movement amount needs to be set.)

Da.2

setting value

Value set with peripheral device

(pulse)

Value set with sequence program 1

(pulse)

ABS Linear 1

: 01

H

ABS Linear 2

: 0A

H

ABS Linear 3

: 15

H

ABS Linear 4

: 1A

H

Current value changing

: 81

H

Set the address

-2147483648 to 2147483647

Set the address

-2147483648 to 2147483647

INC Linear 1

: 02

H

INC Linear 2

: 0B

H

INC Linear 3

: 16

H

INC Linear 4

: 1B

H

Fixed-feed 1

: 03

H

Fixed-feed 2

: 0C

H

Fixed-feed 3

: 17

H

Fixed-feed 4

: 1C

H

Set the movement amount

-2147483648 to 2147483647

Set the movement amount

-2147483648 to 2147483647

Forward run speed/position : 06

H

Reverse run speed/position: 07

H

Forward run position/speed : 08

H

Reverse run position/speed: 09

H

Set the movement amount

0 to 2147483647

Set the movement amount

0 to 2147483647

ABS circular sub

: 0D

H

ABS circular right

: 0F

H

ABS circular left

: 10

H

Set the address

-2147483648 to 2147483647

Set the address

-2147483648 to 2147483647

INC circular sub

: 0E

H

INC circular right

: 11

H

INC circular left

: 12

H

Set the movement amount

-2147483648 to 2147483647

Set the movement amount

-2147483648 to 2147483647

1: Set an integer because the sequence program cannot handle fractions.