15 TROUBLESHOOTING

15.2 List of errors

The following table shows the error details and remedies to be taken when an error

occurs.

Classification

of errors

Error
code

Error name

Error

Operation status at error occurrence

000

(Normal status)

001

Faults

Fatal errors

002

Internal circuit fault

Hardware is faulty.

The system stops.

101

PLC READY OFF
during operation

A PLC READY signal (Y0) is turned
OFF during operation.

The system stops with the setting
(deceleration stop/sudden stop) of the
detailed parameter 2 Sudden stop
selection (stop group 2).
(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)

102

Drive unit READY
OFF

The drive unit READY signal is
turned OFF during operation.

The system stops immediately.

103

Test mode faults
during operation

The personal computer cannot
communicate with the CPU unit.

The system stops with the setting
(deceleration stop/sudden stop) of the
detailed parameter 2 Sudden stop
selection (stop group 2).
(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)

104

Hardware stroke
limit (+)

The hardware stroke limit (upper limit
signal FLS) is turned OFF.

105

Hardware stroke
limit (–)

The hardware stroke limit (lower limit
signal RLS) is turned OFF.

The system stops with the setting
(deceleration stop/sudden stop) of the
detailed parameter 2 Sudden stop
selection (stop group 1).
(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)

106

Stop signal ON at
start

Start is requested when a stop signal
is turned ON.

The system does not start positioning.

Common

107

READY OFF

ON

during BUSY

The PLC READY signal is turned
from OFF to ON when BUSY signal
is turned ON.

The QD75 READY signal (X0) is not
turned ON.

OPR

201

Start at OP

When the OPR retry invalid is set,
the near-point dog machine OPR is
started with the OPR complete flag
turned ON.

The machine OPR is not started.