APPENDICES

Setting range

Item

mm

inch

degree

pulse

Pr.43

OPR method

0: Near-point dog method

1: Stopper method 1) (By dwell time elapse)

2: Stopper method 2) (By OP signal when stopper is hit)

3: Stopper method 3) (Without near-point dog method)

4: Count method 1) (Use zero signal)

5: Count method 2) (Do not use zero signal)

Pr.44

OPR direction

0: Positive direction (address increment direction)

1: Negative direction (address decrement direction)

Pr.45

OP address

–2147483648 to
2147483647

×

10

-1

µ

m

–2147483648 to
2147483647

×

10

-5

inch

0 to 35999999

×

10

-5

degree

–2147483648 to
2147483647
pulse/s

Pr.46

OPR speed

Pr.47

Creep speed

1 to 2000000000

×

10

-2

mm/min

1 to 2000000000

×

10

-3

inch/min

1 to 2000000000

×

10

-3

degree/min

1 to 1000000
pulse/s

O

P

R

basic parameters

Pr.48

OPR retry

0: Do not retry OPR with upper/lower limit switch

1: Retry OPR with upper/lower limit switch

Pr.49

OPR dwell time

0 to 65535ms

Pr.50

Setting for the movement amount
after near-point dog ON

0 to 2147483647

×

10

-1

µ

m

0 to 2147483647

×

10

-5

inch

0 to 2147483647

×

10

-5

degree

0 to 2147483647
pulse

Pr.51

OPR acceleration time selection

Pr.52

OPR deceleration time selection

0 to 3

Pr.53

OP shift amount

–2147483648 to
2147483647

×

10

-1

µ

m

–2147483648 to
2147483647

×

10

-5

inch

0 to 35999999

×

10

-5

degree

–2147483648 to
2147483647
pulse

Pr.54

OPR torque limit value

0 to 300%

Pr.55

Deviation counter clear signal
output time

1 to 65535ms

Pr.56

Speed designation during OP shift 0: OPR speed 1: Creep speed

O

P

R

detailed parameters

Pr.57

Dwell time during OPR retry

0 to 65535ms