5 - 6

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.1.3 Setting items for OPR parameters

When carrying out "OPR control", the "OPR parameters" must be set. The setting

items for the "OPR parameters" are shown below.

The "OPR parameters" are set commonly for each axis.

Refer to Chapter 8 "OPR control" for details on the "OPR control", and to Section 5.2

"List of parameters" for details on each setting item.

OPR control

OPR parameters

Machine OPR control

Fast

OPR control

Pr.43

OPR method

Near

-poi

nt

dog

m

e

thod

S

topper m

e

thod

1)

S

topper m

e

thod

2)

S

topper m

e

thod

3)

Count

m

e

thod 1)

Count

m

e

thod 2)

Pr.44

OPR direction

Pr.45

OP address

Pr.46

OPR speed

Pr.47

Creep speed

OP

R bas

ic

param

et

ers

Pr.48

OPR retry

R

R

R

R

R

Pr.49

OPR dwell time

Pr.50

Setting for the movement amount after near-
point dog ON

Pr.51

OPR acceleration time selection

Pr.52

OPR deceleration time selection

Pr.53

OP shift amount

S

S

S

S

S

S

Pr.54

OPR torque limit value

Pr.55

Deviation counter clear signal output time

C

C

C

C

C

Pr.56

Speed designation during OP shift

S

S

S

S

S

S

OP

R det

ai

led param

et

ers

Pr.57

Dwell time during OPR retry

R

R

R

R

R

: Always set
: Preset parameters are used for machine OPR control.

– : Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or

within the setting range, there is no problem.)

R : Set when using the "12.2.1

OPR

retry function". ("–" when not set.)

S : Set when using the "12.2.2

OP

shift function". ("–" when not set.)

C : Set the deviation counter clear signal output time. (Read as "–" when the setting is not required.)

Checking the OPR parameters.

Pr.43

to

Pr.57

are checked with the following timing.

(1) When the "PLC READY signal [Y0]" output from the PLC CPU to the QD75

changes from OFF to ON

(2) When the test operation button is turned ON in the test mode using GX

Configurator-QP

(3) When an error check is carried out with GX Configurator-QP