Melsec-q, Appendices – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 695

Advertising
background image

Appendix - 53

MELSEC-Q

APPENDICES

Buffer memory address

A1SD75

QD75

Items of A1SD75

Axis 1

Axis 2

Axis 3

Axis 1

Axis 2

Axis 3

Pr.28

Acceleration time 3

40

41

190

191

340

341

40

41

190

191

340

341

Pr.29

Deceleration time 1

42

43

192

193

342

343

42

43

192

193

342

343

Pr.30

Deceleration time 2

44

45

194

195

344

345

44

45

194

195

344

345

Pr.31

Deceleration time 3

46

47

196

197

346

347

46

47

196

197

346

347

Pr.32

JOG speed limit value

48

49

198

199

348

349

48

49

198

199

348

349

Pr.33

JOG operation acceleration time selection

50

200

350

50

200

350

Pr.34

JOG operation deceleration time selection

51

201

351

51

201

351

Pr.35

Acceleration/deceleration process selection

52

202

352

52

202

352

Pr.36

S-pattern proportion

53

203

353

53

203

353

Pr.37

Sudden stop deceleration time

54

55

204

205

354

355

54

55

204

205

354

355

Pr.38

Stop group 1 sudden stop selection

56

206

356

56

206

356

Pr.39

Stop group 2 sudden stop selection

57

207

357

57

207

357

Pr.40

Stop group 3 sudden stop selection

58

208

358

58

208

358

Pr.41

Positioning complete signal output time

59

209

359

59

209

359

Pr.42

Allowable circular interpolation error width

60

61

210

211

360

361

60

61

210

211

360

361

Pr.43

External start function selection

(QD75: Pr.42 External command function selection)

62

212

362

62

212

362

Pr.44

Near pass mode selection for path control

66

216

366

Pr.45

OPR method

70

220

370

70

220

370

Pr.46

OPR direction

71

221

371

71

221

371

Pr.47

OP address

72

73

222

223

372

373

72

73

222

223

372

373

Pr.48

OPR speed

74

75

224

225

374

375

74

75

224

225

374

375

Pr.49

Creep speed

76

77

226

227

376

377

76

77

226

227

376

377

Pr.50

OPR retry

78

228

378

78

228

378

Pr.51

OPR dwell time

79

229

379

79

229

379

Pr.52

Setting for the movement amount after near-

point dog ON

80

81

230

231

380

381

80

81

230

231

380

381

Pr.53

OPR acceleration time selection

82

232

382

82

232

382

Pr.54

OPR deceleration time selection

83

233

383

83

233

383

Pr.55

OP shift amount

84

85

234

235

384

385

84

85

234

235

384

385

Pr.56

OPR torque limit value

86

236

386

86

236

386

Pr.57

Speed designation during OP shift

88

238

388

88

238

388

Pr.58

Dwell time during OPR retry

89

239

389

89

239

389

Advertising