Melsec-q, Appendices – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 701

Advertising
background image

Appendix - 59

MELSEC-Q

APPENDICES

Buffer memory address

A1SD75

QD75

Items of A1SD75

Axis 1

Axis 2

Axis 3

Axis 1

Axis 2

Axis 3

Da.10

Shape

Da.11

Start data No.

Da.12

Special start

instruction

Da.13

Parameter

1st

point

4300 4350 4550 4600 4800 4850

26000

26050

27000

27050

28000

28050

2nd point

4301 4351 4551 4601 4801 4851

26001

26051

27001

27051

28001

28051

3rd point

4302 4352 4552 4602 4802 4852

26002

26052

27002

27052

28002

28052

to

to

to

to

to

to

to

S

tart

bl

oc

k dat

a

2

50th point

4349 4399 4599 4649 4849 4899

26049

26099

27049

27099

28049

28099

Da.14

Condition target

Da.15

Condition operator

4400

4650

4900

26100

27100

28100

Da.16

Address

4402

4403

4652

4653

4902

4903

26102

26103

27102

27103

28102

28103

Da.17

Parameter 1

4404

4405

4654

4655

4904

4905

26104

26105

27104

27105

28104

28105

Da.18

Parameter 2

No. 1

4406

4407

4656

4657

4906

4907

26106

26107

27106

27107

28106

28107

No. 2

4410 to

4419

4660 to

4669

4910 to

4919

26110 to

26119

27110 to

27119

28110 to

28119

No. 3

4420 to

4429

4670 to

4679

4920 to

4929

26120 to

26129

27120 to

27129

28120 to

28129

to

to

to

to

to

to

to

P

o

s

it

ioni

ng s

tart

i

n

fo

rm

at

ion

2

Condi

ti

on dat

a

No. 10

4490 to

4499

4740 to

4749

4990 to

4999

26190 to

26199

27190 to

27199

28190 to

28199

Start No. 8001

4500

4750

5000

Start No. 8002

4501

4751

5001

to

to

to

to

to

to

to

P

o

s

it

ioni

ng

sta

rt

in

fo

rm

a

tio

n

Indirect

specification

Start No. 8050

4549

4799

5049

5050

30000

to

to

PLC CPU

memo area

Condition judgment target data of
the condition data

5099

30099

Target axis

5100

Head positioning block No.

5101

No. of read/write data items

5102

Read/write request

5103

Read/write block

5110 to 6109

2: With the QD75, it is called "block start data".

3: With the QD75, the "block start data" and "condition data" in the shaded area are called "start block 0". There are five start blocks: 0 to

4.

Refer to Appendix 12 "List of buffer memory addresses" for details.

Advertising