Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 408

Advertising
background image

9 - 108

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Setting method for the current value changing function

The following shows an example of a sequence program and data setting to
change the current value to a new value with the positioning start signal. (The

"

Md.20

Current feed value is changed to "5000.0

µ

m" in the example shown.)

(1) Set the following data.

(Set with the sequence program shown in (3), while referring to the start time
chart shown in (2).)

Buffer memory address

Setting item

Setting

value

Setting details

Axis 1 Axis 2 Axis 3 Axis 4

Cd.3

Positioning start No.

9003

Set the start No. "9003" for the new current value.

1500

1600

1700

1800

Cd.9

Current value changing

50000

Set the new " Md.20 Current feed value".

1506

1507

1606

1607

1706

1707

1806

1807

Refer to Section 5.7 "List of control data" for details on the setting details.

(2) The following shows a start time chart.

Positioning start signal

PLC READY signal

QD75 READY signal

Start complete signal

BUSY signal

Positioning complete signal

9003

V

t

Error detection signal

50000

Start of data No. 9003

Data No. during positioning execution

Address during positioning execution

Md.20 Current feed value

Cd.3 Positioning start No.

Cd.9 Current value changing

50000

[Y10]

[Y0]

[X0]

[X10]

[XC]

[X14]

[X8]

Fig. 9.21 Changing to a new current value using the start No. (No. 9003) for a current value changing