5 - 111

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting value

Default value

Storage buffer

memory address

(common to axes 1

to 4)

Set with a decimal.

Setting
value

K

1

Flash ROM write request

1: Requests write access to flash ROM.

The QD75 resets the value to "0" automatically when the write access completes.

(This indicates the completion of write operation.)

0

1900

Set with a decimal.

Setting
value

K

Parameter initialization request

1: Requests parameter initialization.

The QD75 resets the value to "0" automatically when the initialization completes.

(This indicates the completion of parameter initialization.)

1

0

1901

Set with a decimal.

Setting
value

K

Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid

0

1905

Set with a decimal.

Setting
value

K

Stop command processing for deceleration stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation

0