5 - 11

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.1.6 Setting items for condition data

When carrying out "high-level positioning control" or using the JUMP instruction in the

"major positioning control", the "condition data" must be set as required. The setting

items for the "condition data" are shown below.

Up to 10 "condition data" items can be set for each axis.

Refer to Chapter 10 "High-level Positioning Control" for details on the "high-level

positioning control", and to Section 5.5" List of condition data" for details on each

setting item.

Major positioning

control

High-level positioning control

Control

Condition data

Other than

JUMP

instruction

JUMP

instruction

Block start

(Normal

start )

Condition

start

Wait start

Simul-

taneous

start

Repeated

start

(FOR

loop)

Repeated

start

(FOR

condition)

Da.15

Condition target

Da.16

Condition operator

Da.17

Address

Da.18

Parameter 1

Da.19

Parameter 2

: Set as required ("–" when not set)
: Setting limited

– : Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the

setting range, there is no problem.)

Checking the condition data

Da.15

to

Da.19

are checked with the following timing.

(1) When the " Block start data" starts
(2) When "JUMP instruction" starts
(3) When an error check is carried out with GX Configurator-QP