Melsec-q, 5 data used for positioning control, Da.18 parameter 1 – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 173: Da.19 parameter 2

Advertising
background image

5 - 85

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Da.18 Parameter 1

Set the parameters as required for the "

Da.16

Condition operator".

Da.16

Condition operator

Setting value

Setting details

01

H

:

∗∗

=P1

02

H

:

∗∗≠

P1

03

H

:

∗∗≤

P1

04

H

:

∗∗≥

P1

05

H

: P1

≤∗∗≤

P2

06

H

:

∗∗≤

P1, P2

≤∗∗

Value

The value of P1 should be equal to or smaller than the value of
P2. (P1

P2)

If P1 is greater than P2 (P1>P2), the "condition data error" (error
code 533) will occur.

07

H

: DEV=ON

08

H

: DEV=OFF

Value

(bit No.)

Set the device bit No.

X: 0

H

to 1

H

, 4

H

to 11

H

Y: 0, 4

H

to 17

H

10

H

: Axis 1 selected

E0

H

: Axes 2, 3, and 4 selected

Value

(positioning data No.)

Set the positioning data No. for starting axis 1 and/or axis 2.

Low-order 16-bit

: Axis 1 positioning data No. 1 to 600 (01

H

to 258

H

)

High-order 16-bit

: Axis 2 positioning data No. 1 to 600 (01

H

to 258

H

)

Da.19 Parameter 2

Set the parameters as required for the "

Da.16

Condition operator".

Da.16

Condition operator

Setting value

Setting details

01

H

:

∗∗

=P1

02

H

:

∗∗≠

P1

03

H

:

∗∗≤

P1

04

H

:

∗∗≥

P1

Not used. (No need to be set.)

05

H

: P1

≤∗∗≤

P2

06

H

:

∗∗≤

P1, P2

≤∗∗

Value

The value of P2 should be equal to or greater than the value of
P1. (P1

P2)

If P1 is greater than P2 (P1>P2), the "condition data error" (error
code 533) will occur.

07

H

: DEV=ON

08

H

: DEV=OFF

10

H

: Axis 1 selected

20

H

: Axis 2 selected

30

H

: Axes 1 and 2 selected

Not used. (No need to be set.)

40

H

: Axis 3 selected

50

H

: Axes 1 and 3 selected

60

H

: Axes 2 and 3 selected

70

H

: Axes 1, 2, and 3 selected

80

H

: Axis 4 selected

90

H

: Axes 1 and 4 selected

A0

H

: Axes 2 and 4 selected

B0

H

: Axes 1, 2, and 4 selected

C0

H

: Axes 3 and 4 selected

D0

H

: Axes 1, 3, and 4 selected

E0

H

: Axes 2, 3, and 4 selected

Value

(positioning data No.)

Set the positioning data No. for starting axis 3 and/or axis 4.

Low-order 16-bit

: Axis 3 positioning data No. 1 to 600 (01

H

to 258

H

)

High-order 16-bit

: Axis 4 positioning data No. 1 to 600 (01

H

to 258

H

)