3 outline of stopping, Melsec-q, 1 product outline 1.2.3 outline of stopping – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 40

Advertising
background image

1 - 20

MELSEC-Q

1 PRODUCT OUTLINE

1.2.3 Outline of stopping

Each control is stopped in the following cases.

(1) When each control is completed normally.

(2) When the drive unit READY signal is turned OFF.

(3) When a PLC CPU error occurs

(4) When the PLC READY signal is turned OFF.

(5) When an error occurs in the QD75.

(6) When control is intentionally stopped (Stop signal from PLC CPU turned ON, stop

signal from an external device, etc.)

The outline for the stopping process in these cases is shown below. (Excluding (1) for

normal stopping.)

Stop process

OPR control

Manual control

Stop cause

Stop

axis

M code

ON signal

after stop

Axis

operation

status

after

stopping

(

Md.26

)

Machine

OPR

control

Fast

OPR

control

Major
positioning
control

High-level
positioning
control

JOG/
Inching
operation

Manual
pulse
generator
operation

Forced stop

Drive unit
READY
signal OFF

Each
axis

No
change

During
error

Immediate stop

Deceleration
stop

Fatal stop
(Stop group 1)

Hardware
stroke limit
upper/lower
limit error
occurrence

Each
axis

No
change

During
error

Deceleration stop/sudden stop

(Select with “

Pr.37

Sudden stop group1

sudden stop selection” )

Deceleration

stop

PLC CPU
error
occurrence

No
change

PLC READY
signal OFF

Turns
OFF

Emergency
stop
(Stop group 2)

Error in test
mode

All
axes

No
change

During
error

Deceleration stop/sudden stop

(Select with “

Pr.38

Sudden stop group2

sudden stop selection” )

Deceleration

stop

Axis error
detection
(Error other
than stop
group 1 or 2)

Relatively safe
stop
(Stop group 3) “Stop signal”

from
peripheral
device

Each
axis

No
change

During
error

"Stop signal"
ON from
external
source

Intentional stop
(Stop group 3) "Axis stop

signal" ON
from PLC
CPU

Each
axis

No
change

When
stopped
(While
waiting)

Deceleration stop/sudden stop

(Select with “

Pr.39 Sudden stop group3

sudden stop selection”)

Deceleration

stop

Advertising