(4) When either of three axes exceeds the speed limit, that axis is controlled with

the speed limit value. The speeds of the other axes are limited at the ratios of

" Da.8 Command speed".

(Examples)

Axis

Setting item

Axis 1 setting

Axis 2 setting

Axis 3 setting

Pr.8

Speed limit

value

4000.00mm/min

5000.00mm/min

6000.00mm/min

Da.8

Command

speed

8000.00mm/min

6000.00mm/min

4000.00mm/min

With the settings shown above, the operation speed in speed control is as
follows.

Axis 1: 4000.00 mm/min (Speed is limited by Pr.8 ).

Axis 2: 3000.00 mm/min (Speed is limited at ratios in axes 1, 2, and 3

command speeds).

Axis 3: 2000.00 mm/min (Speed is limited at ratios in axes 1, 2, and 3

command speeds).

(5) An error "No command speed" (error code: 503) will occur if a current speed

(-1) is set in " Da.8 Command speed".

(6) The software stroke limit check is not carried out when the control unit is set to

"degree".