1 data required for major positioning control, Melsec-q, Remark – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 304

Advertising
background image

9 - 4

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.1.1 Data required for major positioning control

The following table shows an outline of the "positioning data" configuration and setting

details required to carry out the "major positioning controls".

Setting item

Setting details

Da.1

Operation pattern

Set the method by which the continuous positioning data (Ex: positioning data No. 1,
No. 2, No. 3) will be controlled. (Refer to Section 9.1.2.)

Da.2

Control system

Set the control system defined as a "major positioning control". (Refer to Section 9.1.)

Da.3

Acceleration time No.

Select and set the acceleration time at control start. (Select one of the four values set

in

Pr.9

,

Pr.25

,

Pr.26

, and

Pr.27

for the acceleration time.)

Da.4

Deceleration time No.

Select and set the deceleration time at control stop. (Select one of the four values set

in

Pr.10

, Pr.28 ,

Pr.29

, and

Pr.30

for the deceleration time.)

Da.5

Axis to be
interpolated

Set an axis to be interpolated (partner axis) during the 2-axis interpolation operation
(Refer to Section 9.1.6).

Da.6

Positioning address/
movement amount

Set the target value during position control. (Refer to Section 9.1.3.)

Da.7

Arc address

Set the sub point or center point address during circular interpolation control.

Da.8

Command speed

Set the speed during the control execution.

Da.9

Dwell time

Set the time the machine waits from the completion of the executed positioning control
and the stopping of the workpiece until the judgment of the QD75 positioning
completion.

Positioning dat

a N

o

. 1

Da.10

M code

Set this item when carrying out sub work (clamp and drill stops, tool replacement, etc.)
corresponding to the code No. related to the positioning data execution.

The settings and setting requirement for the setting details of

Da.1

to

Da.10

differ according to the

"

Da.2

Control system". (Refer to Section 9.2 "Setting the positioning data".)

Major positioning control sub functions

Refer to Section 3.2.4 "Combination of QD75 major functions and sub functions"
for details on "sub functions" that can be combined with the major positioning
control.
Also refer to Chapter 12 "Control sub Functions" for details on each sub function.

Major positioning control from peripheral devices

"Major positioning control" can be executed from the peripheral device test mode.
Refer to GX Configurator-QP Operating Manual for details on carrying out major
positioning control from the peripheral device.

REMARK

600 positioning data (positioning data No. 1 to 600) items can be set per axis.

Advertising