5 - 10

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.1.5 Setting items for block start data

The "block start data" must be set when carrying out "high-level positioning control".

The setting items for the " block start data" are shown below.

Up to 50 points of " block start data" can be set for each axis.

Refer to Chapter 10 "High-level Positioning Control" for details on the "high-level

positioning control", and to Section 5.4 "List of block start data" for details on each

setting item.

High-level positioning

control

Block start data

Block start

(Normal start)

Condition

start

Wait start

Simultaneous

start

Repeated

start

(FOR loop)

Repeated

start

(FOR

condition)

Da.11

Shape (end/continue)

Da.12

Start data No.

Da.13

Special start instruction

Da.14

Parameter

: Set as required ("–" when not set)

– : Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the

setting range, there is no problem.)

Checking the block start data

Da.11

to

Da.14

are checked with the following timing.

(1) When the "Block start data" starts
(2) When an error check is carried out with GX Configurator-QP