Melsec-q, 15 troubleshooting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 635

Advertising
background image

15 - 31

MELSEC-Q

15 TROUBLESHOOTING

Related buffer memory

address

Axis 1 Axis 2 Axis 3 Axis 4

Set range

(Setting with sequence program)

Remedy

71

221

371

521

0, 1

72
73

222
223

372
373

522
523

• [mm] [inch] [pulse]

–2147483648 to 2147483647

• [degree] 0 to 35999999

With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.

74
75

224
225

374
375

524
525

1 to 1000000 [pulse/s]

1 to 2000000000 [mm/min or others]

• Bring the setting into the setting range.

• Set the speed to the bias speed at start or higher.

(Refer to Section 5.2.5)

76
77

226
227

376
377

526
527

1 to 1000000 [pulse/s]

1 to 2000000000 [mm/min or others]

• Bring the setting into the setting range.

• Set the speed to that below the OPR speed.

• Set the value to the bias speed at start or higher.

(Refer to Section 5.2.5)

78

228

378

528

0, 1

79

229

379

529

0 to 65535

80
81

230
231

380
381

530
531

0 to 2147483647

82

232

382

532

0, 1, 2, 3

83

233

383

533

0, 1, 2, 3

86

236

386

536

1 to 300

87

237

387

537

1 to 65535

88

238

388

538

0, 1

With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.

Advertising