4 outline for restarting, Melsec-q, 1 product outline 1.2.4 outline for restarting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 41: When " cd.6 restart command" is on, Reference

Advertising
background image

1 - 21

MELSEC-Q

1 PRODUCT OUTLINE

1.2.4 Outline for restarting

When a stop cause has occurred during operation with position control causing the

axis to stop, positioning to the end point of the positioning data can be restarted from

the stopped position by using the " Cd.6 Restart command".

If issued during a continuous positioning or continuous path control operation, the

restart command will cause the positioning to be re-executed using the

current position (pointed by the positioning data No. associated with the

moment when the movement was interrupted) as the start point.

When " Cd.6 Restart command" is ON

(1) If the "

Md.26

Axis operation status" is stopped, positioning to the end point of

the positioning data will be restarted from the stopped position regardless of
the absolute system or incremental system.

(2) When "

Md.26

Axis operation status" is not stopped, the warning "Restart not

possible" (warning code: 104) will be applied, and the restart command will be
ignored.

[Example for incremental system]

(a) The restart operation when the axis 1 movement amount is 300, and the

axis 2 movement amount is 600 is shown below.

Start point
address

Stop position due to stop cause

Designated end
point position

Axis 1

400

200

100

100

300

700

Axis 2

Stop position due to stop cause

Stop position
after restart

Axis 1

400

200

100

100

300

700

Axis 2

Restart

Operation during
restart

Reference

If the positioning start signal [Y10 to Y13]/external command signal is turned ON

while the "

Md.26

Axis operation status" is waiting or stopped, positioning will be

restarted from the start of the positioning start data regardless of the absolute
system or incremental system. ( : When the external command signal is set to
"External positioning start")
(Same as normal positioning.)

[Example for incremental system]

(a) The positioning start operation when the axis 1 movement amount is 300

and the axis 2 movement amount is 600 is shown below.

Start point
address

Stop position due to stop cause

Designated end
point position

Axis 1

400

200

100

100

300

700

Axis 2

Stop position due to stop cause

Stop position
after restart

Axis 1

500

200

100

100

300

900

Axis 2

Positioning
start

Operation during
positioning start

Advertising