11 - 3

MELSEC-Q

11 MANUAL CONTROL

[3] Manual pulse generator operation

"Manual pulse generator operation" is a control method in which positioning is

carried out in response to the No. of pulses input from a manual pulse generator

(the No. of input pulses is output). This operation is used for manual fine

adjustment, etc., when carrying out accurate positioning to obtain the positioning

address.

M

Movement in response
to the command pulses

QD75

Output pulses

Manual pulse generator

Pulse input

Fig. 11.3 Manual pulse generator control

Manual control sub functions

Refer to Section 3.2.4 "Combination of QD75 major functions and sub functions"
for details on "sub functions" that can be combined with manual control. Also refer
to Chapter 12 "Control sub functions" for details on each sub function.

Carrying out manual control from peripheral devices

"JOG operation", "Inching operation" and enabling/disabling of the "manual pulse
generator operation" can be executed from GX Configurator-QP test mode.
Refer to GX Configurator-QP Operating Manual for details on manual control from
GX Configurator-QP.

Monitoring manual control

Refer to Section 5.6 "List of monitor data" when directly monitoring the buffer
memory using GX Developer.
Also refer to GX Configurator-QP Operating Manual when monitoring with the
monitor functions of GX Configurator-QP.

Advertising