Melsec-q, 14 dedicated instructions [control data, Functions – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 586

Advertising
background image

14 - 4

MELSEC-Q

14 DEDICATED INSTRUCTIONS

[Control data]

Device

Item

Setting data

Setting range

Setting side

( 1)

(S)+0

System area

(S)+1

Complete status

The state at the time of completion is stored.

• 0

: Normal completion

• Other than 0 : Abnormal completion (error code)( 2)

System

(S)+2

Signal received from
servo amplifier

The following signal states taken in from the servo
amplifier to the input module are written.

• b0: ABS data bit 0
• b1: ABS data bit 1
• b2: Transmission data READY flag

b0: 0/1
b1: 0/1
b2: 0/1

User

(S)+3

Signal transmitted to
servo amplifier

The ON/OFF states of the following data which are
calculated using the dedicated instructions by the
"signals received from the servo amplifier" and output to
the servo amplifier are stored.

• b0: Servo amplifier ON
• b1: ABS transfer mode
• b2: ABS request flag

System

(S)+4

Status

Status of communication with servo amplifier

• 0

: Communication completed

(Set by user at communication start)

• Other than 0 : During communication (System stores)

0

User/system

(S)+5 to

(S)+7

System area

1: The data on the setting side is as follows.

• User

: Data before the execution of dedicated instructions is stored by user.

• System: Data after the execution of dedicated instruction is stored by PLC CPU.

2: Refer to Section 15.2 for error codes at abnormal completion.

[Functions]

(1) The positioning data is read from the servo amplifier capable of processing the

absolute positions of the axes to be set (See below), and the values converted with

respect to a unit are stored in "

Md.20

current feed value" and "

Md.21

machine

feed value" area of the QD75.

• ABRST1: Axis 1

• ABRST2: Axis 2

• ABRST3: Axis 3

• ABRST4: Axis 4

For absolute position detection system, carry out the absolute position restoration

operation each time the power is turned ON or PLC CPU is reset.

(S)+0
(S)+1
(S)+2
(S)+3
(S)+4
(S)+5

(S)+7

Control data

PLC CPU

Current

feed value

Input module

Output module

Servo amplifier

QD75

Current value data

ABRST

Machine

feed value

Advertising