15 - 20

MELSEC-Q

15 TROUBLESHOOTING

Classification

of errors

Error
code

Error name

Error

Operation status at error occurrence

533

Condition data error

• The condition setting values are not

set or outside the setting range.

• The condition operator setting

values are not set or outside the
setting range.

• The condition operator is a bit

operator, and the parameter 1 is 32
or more.

• An unusable condition operator is

set for the set condition.

• The conditional operator has been

[parameter 1 parameter 2] with
05H (P1

**

P2).

534

Special start
instruction error

• The partner axis designation for

simultaneous start includes the
self-axis.

• No applicable special start

instruction is present.

535

Circular interpolation
not possible

Circular interpolation is carried out
on an axis in the unit of degree.

The operation is terminated.

536

M code ON signal
start

The positioning start is carried out
when an M code ON signal (X4 to
X7) is turned ON.

537

PLC READY OFF
start

The positioning start is carried out
when the PLC READY signal (Y0) is
turned OFF.

538

READY OFF start

The positioning start is carried out
when the QD75 READY signal (X0)
is turned OFF.

543

Outside start No.
range

• At the start of positioning, the

setting value of the "positioning
start No." of the axis control data is
outside the ranges of 1 to 600,
7000 to 7004, and 9000 to 9004.

• At a Pre-reading start, the

"positioning start No." setting of the
axis control data is other than 1 to
600.

At start, the system will not operate.

544

Outside radius range The arc radius exceeds 536870912.

At start: The system will not operate.
During operation:

The system stops
immediately.

Positioning

operation

545

Control system
LOOP setting error

A "0" is set in the control system
"LOOP".

The operation is terminated.