12 - 35

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[2] Precautions during control

(1) Control is carried out as follows at the speed change during continuous path

control.
a) When no speed designation (current speed) is provided in the next

positioning data:

The next positioning data is controlled at the "

Cd.14

New speed

value".

b) When a speed designation is provided in the next positioning data:

The next positioning data is controlled at its command speed

( Da.8 ).

Positioning control

P1

Designated speed in P2

Cd. 14 New speed value

Next control

P2

Speed change

command

Designated speed in P1

[a] When no speed designation
(current speed) is provided.
[b] When a speed designation
is provided.

Fig. 12.23 Speed change during continuous path control

(2) When changing the speed during continuous path control, the speed change

will be ignored if there is not enough distance remaining to carry out the
change.

(3) When the stop command was given to make a stop after a speed change

that had been made during position control, the restarting speed depends
on the function version.

Function version

Restarting speed

A

Da.8

Command speed

B or later

Cd.14 New speed value

Refer to Section 2.4 for the way to check the function version.

V

t

Speed change
command

Stop command

Restarting
command

Cd. 14 New speed value

Command speed

Da. 8

Fig. 12.24 Restarting speed after speed change made during position control (Function version B)