15 - 10

MELSEC-Q

15 TROUBLESHOOTING

Classification

of errors

Error
code

Error name

Error

Operation status at error occurrence

<When blocks are started

simultaneously>

• The partner axis for simultaneous

start is BUSY.

501

Error before
simultaneous start

<When multiple axes are started and

controlled simultaneously>

• The partner axis for simultaneous

start is BUSY.

• The "Simultaneous start axis start

data No." of the start axis is 0 or is
outside the setting range.

• The "Simultaneous start axis start

data No." of those axes other than
the start axis is outside the setting
range.

At start: The system will not operate.

During operation:

The system stops
immediately.

502

Illegal data No.

• The positioning data No. tried to be

executed is outside the ranges of 1
to 600, 7000 to 7004, and 9001 to
9004.

• The designation of a JUMP

destination is executed currently.

• The designation of a JUMP

destination is outside the ranges of
1 to 600.

The positioning data is not executed.

Positioning

operation

503

No command speed

• At the start of positioning, a current

speed (–1) is set for the command
speed of the positioning data to be
initially executed.

• The current speed is set by speed

control.

• The current speed is set for speed-

position switching control.

At the start of positioning, operation
does not start.