Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 513

Advertising
background image

12 - 37

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[3] Setting the speed change function from the PLC CPU

The following shows the data settings and sequence program example for

changing the control speed of axis 1 from the PLC CPU. (In this example, the

control speed is changed to "20.00mm/min".)

(1) Set the following data.

(Use the start time chart shown in section (2) below as a reference, and set

using the sequence program shown in section (3).)

Buffer memory address

Setting item

Setting

value

Setting details

Axis

1

Axis

2

Axis

3

Axis

4

Cd.14

New speed value

2000

Set the new speed.

1514

1515

1614

1615

1714

1715

1814

1815

Cd.15

Speed change
request

1

Set "1: Change the speed".

1516 1616 1716 1816

Refer to Section 5.7 "List of control data" for details on the setting details.

(2) The following shows the speed change time chart.

Cd. 15 Speed change request

Cd. 14 New speed value

In speed change
processing flag

BUSY signal

QD75 READY signal

Error detection signal

V

t

1

0

0

1

0

2000

0

Start complete signal

Dwell time

PLC READY signal

Positioning start signal

Positioning complete signal

[Y10]

[Y0]

[X0]

[X10]

[XC]

[X14]

[X8]

Md. 40

Fig. 12.26 Time chart for changing the speed from the PLC CPU

Advertising