12 - 9

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[2] Setting range for the OP shift amount

Set the OP shift amount within the range from the detected zero signal to the

upper/lower limit switches.

Setting range of the
negative OP
shift amount

Setting range of the positive OP shift amount

Address decrease
direction

Upper limit

Lower limit

Near-point dog

Pr. 44 OPR direction

Zero signal

Address increase
direction

Fig. 12.5 Setting range for the OP shift amount

[3] Movement speed during OP shift

When using the OP shift function, the movement speed during the OP shift is set

in "

Pr.56

Speed designation during OP shift". The movement speed during the

OP shift is selected from either the "

Pr.46

OPR speed" or the "

Pr.47

Creep

speed".

The following drawings show the movement speed during the OP shift when a

mechanical OPR is carried out by the near-point dog method.

(1) OP shift operation at the "

Pr.46

OPR speed"

(When "

Pr.56

speed designation during OP shift" is 0)

OP

When the " Pr. 53 OP
shift amount" is positive

When the " Pr. 53 OP
shift amount" is negative

Pr. 44 OPR
direction

Machine OPR start

Pr. 46 OPR
speed

Near-point dog

Zero signal

Fig. 12.6 OP shift operation at the OPR speed

Advertising