5 - 119

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Setting value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Set with a decimal.

Setting value

Override value (%)

1 to 300

K

100

1513

1613

1713

1813

Set with a decimal.

Actual value

Conversion into an integer value

Cd.14 New speed value

10

n

Unit conversion table ( Cd.14 )

n

-2

mm/min

-3

inch/min

-3

degree/min

0

pulse/s

Unit

R

Setting value

(Decimal)

Example: When the " Cd. 14 New speed

value" is set as "20000.00mm

/min", the buffer memory

stores "2000000".

0

1514
1515

1614
1615

1714
1715

1814
1815

Set with a decimal.

Setting
value

Speed change request
1: Executes speed change.

K

The QD75 resets the value to "0" automatically

when the speed change request has been processed.

(This indicates the completion of speed change request.)

1

0

1516

1616

1716

1816