15 TROUBLESHOOTING

Related buffer memory

address

Axis 1 Axis 2 Axis 3 Axis 4

Set range

(Setting with sequence program)

Remedy

20
21

170
171

320
321

470
471

• [mm] [inch] [pulse]

–2147483648 to 2147483647

• [degree] 0 to 35999999

• Bring the setting into the setting range.

• In a unit other than degree, set so that the lower limit

value is smaller than the upper limit value.

22

172

322

472

0, 1

23

173

323

473

0, 1

24
25

174
175

324
325

474
475

1 to 2147483647

26

176

326

476

1 to 500

27

177

327

477

0, 1

28

178

328

478

0, 1

29

179

329

479

0, 1

30

180

330

480

0, 1, 2

33

0, 1, 2, 3

With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.

34

184

334

484

0, 2

Speed-position switching control (ABS mode) should
satisfy the conditions 1) to 3) given on the left. When
speed-position switching control (ABS mode) is not to
be exercised, set 0 to speed-position function selection
and turn the PLC READY signal (Y0) from OFF to ON.

36
37

186
187

336
337

486
487

1 to 8388608

38
39

188
189

338
339

488
489

1 to 8388608

40
41

190
191

340
341

490
491

1 to 8388608

42
43

192
193

342
343

492
493

1 to 8388608

With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.