14 - 13

MELSEC-Q

14 DEDICATED INSTRUCTIONS

[Control data]

Device

Item

Setting data

Setting range

Setting side

( 1)

(S)+0

System area

(S)+1

Complete status

The state at the time of completion is stored.

0

: Normal completion

Other than 0 : Abnormal completion (error code)( 2)

System

(S)+2

Teaching data
selection

The address (positioning address/arc address) to which
the current feed value is written is set.

0: Current feed value is written to positioning address.
1: Current feed value is written to arc address.

0, 1

User

(S)+3

Positioning data No.

The positioning data No. for which teaching is carried out
is set.

1 to 600

User

1: The data on the setting side is as follows.

• User

: Data before the execution of dedicated instructions is stored by user.

• System: Data after the execution of dedicated instruction is stored by PLC CPU.

2: Refer to Section 15.2 for error codes at abnormal completion.

[Functions]

(1) The "current feed value" of the axes to be set (See below) is set in the positioning

address or arc address.

The positioning data other than the positioning addresses and arc addresses are

set by peripheral device or using a sequence program.

• TEACH1: Axis 1

• TEACH2: Axis 2

• TEACH3: Axis 3

• TEACH4: Axis 4

(2) Teaching can be carried out for the positioning data No. 1 to 600.

(3) The movement of the machine to the address (position) set in the positioning

address/arc address of the positioning data is carried out by the JOG operation,

inching operation, or manual pulse generator operation.

(4) The TEACH instruction completion can be confirmed using the complete devices

((D)+0) and ((D)+1).

(a) Complete device ((D)+0)

This device is turned ON by the END processing of the scan for which

TEACH instruction is completed, and turned OFF by the next END

processing.

(b) Complete state display device ((D)+1)

This device is turned ON and OFF according to the state in which TEACH

instruction is completed.

• When completed normally

:Kept unchanged at OFF.

• When completed abnormally:This device is turned ON by the END

processing of the scan for which TEACH

instruction is completed, and turned OFF by

the next END processing. (same ON/OFF

operation as complete device).