Melsec-q, Appendices – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 747

Advertising
background image

Appendix - 105

MELSEC-Q

APPENDICES

Buffer memory address

Axis 1

Axis 2

Axis 3

Axis 4

Item

Memory area

26000

26050

27000

27050

28000

28050

29000

29050

Da.11

Shape

Da.12

Start data No.

Da.13

Specilal start instruction

Da.14

Parameter

1st point

26001

26051

27001

27051

28001

28051

29001

29051

2nd point

26002

26052

27002

27052

28002

28052

29002

29052

3rd point

to

to

to

to

to

26049

26099

27049

27099

28049

28099

29049

29099

50th point

Block start data

Da.15

Condition target

26100

27100

28100

29100

Da.16

Condition operator

26102
26103

27102
27103

28102
28103

29102
29103

Da.17

Address

26104
26405

27104
27405

28104
28405

29104
29405

Da.18

Parameter 1

26106
26107

27106
27107

28106
28107

29106
29107

Da.19

Parameter 2

No

. 1

26110 to 26119 27110 to 27119 28110 to 28119 29110 to 29119

No. 2

26120 to 26129 27120 to 27129 28120 to 28129 29120 to 29129

No. 3

to

to

to

to

to

26190 to 26199 27190 to 27199 28190 to 28199 29190 to 29199

No. 10

C

ondition data

Starting block 0

26200 to 26299 27200 to 27299 28200 to 28299 29200 to 29299

Block start data

26300 to 26399 27300 to 27399 28300 to 28399 29300 to 29399

Condition data

Starting block 1

26400 to 26499 27400 to 27499 28400 to 28499 29400 to 29499

Block start data

26500 to 26599 27500 to 27599 28500 to 28599 29500 to 29599

Condition data

Starting block 2

26600 to 26699 27600 to 27699 28600 to 28699 29600 to 29699

Block start data

26700 to 26799 27700 to 27799 28700 to 28799 29700 to 29799

Condition data

Starting block 3

26800 to 26899 27800 to 27899 28800 to 28899 29800 to 29899

Block start data

26900 to 26999 27900 to 27999 28900 to 28999 29900 to 29999

Condition data

Starting block 4

Positioning dat

a (Starting bloc

k data)