7 list of control data, 1 system control data, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 198

Advertising
background image

5 - 110

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.7 List of control data

5.7.1 System control data

Setting item

Setting details

Cd.1

Flash ROM write request

Requests writing of data (parameters, positioning data, and block start data) from
the buffer memory to the flash ROM.

Requests initialization of setting data.
Initialization: Resetting of setting data to default values

Note: After completing the initialization of setting data, reset the PLC CPU or reboot

the PLC power.

Initialized setting data

Parameters (

Pr.1

to

Pr.57

,

Pr.150

)

Positioning data (No. 1 to No. 600)

Block start data (No. 7000 to 7004)

Cd.2

Parameter initialization request

Cd.41

Deceleration start flag valid

Set whether "

Md.48

Deceleration start flag" is made valid or invalid.

Cd.42

Stop command processing for

deceleration stop selection

Set the stop command processing for deceleration stop function (deceleration
curve re-processing/deceleration curve continuation).