2 axis control data, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 200

Advertising
background image

5 - 112

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.7.2 Axis control data

Setting item

Setting details

Cd.3

Positioning start No.

Set the positioning start No.
(Only 1 to 600 for the Pre-reading start function. For details, refer to Section
12.7.8 "Pre-reading start function".)

Cd.4

Positioning starting point No.

Set a " starting point No." (1 to 50) if block start data is used for positioning.
(Handled as "1" if the value of other than 1 to 50 is set.)

Cd.5

Axis error reset

Clears the axis error detection, axis error No., axis warning detection and axis
warning No.

When the QD75 axis operation state is "in error occurrence", the error is cleared
and the QD75 is returned to the "waiting" state.

Cd.6

Restart command

When positioning is stopped for any reason (when axis operation state is

"stopped"), set "1" in

Cd.6

. Positioning will be carried out again from the stopped

position to the end point of the stopped positioning data.

Cd.7

M code OFF request

The M code ON signal turns OFF.