3 2-axis linear interpolation control, Melsec-q, Operation chart – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 329

Advertising
background image

9 - 29

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.2.3 2-axis linear interpolation control

In "2-axis linear interpolation control" (" Da.2 Control system" = ABS linear 2, INC

linear 2), two motors are used to carry out position control in a linear path while

carrying out interpolation for the axis directions set in each axis.

(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)

[1] 2-axis linear interpolation control (ABS linear 2)

Operation chart

In absolute system 2-axis linear control, addresses established by a machine OPR
on a 2-axis coordinate plane are used. Linear interpolation positioning is carried
out from the current stop position (start point address) to the address (end point

address) set in " Da.6 Positioning address/movement amount".

X

1

X

2

Y

1

Y

2

Reverse direction

Forward direction (X axis)

Reverse direction

Forward direction (Y axis)

Movement by linear interpolation of the X axis and Y axis

Start point address (X

1

,Y

1

)

(current stop position)

Y axis movement

X axis movement amount

amount

End point address (X

2

,Y

2

)

(positioning address)

Example

5000

10000

Axis 2 movement amount

(4000-1000=3000)

4000

1000

Axis 2

Axis 1

0

(current stop position)

End point address

When the start point address (current stop position) is (1000, 1000) and the end point address
(positioning address) is (10000, 4000), positioning is carried out as follows.

Axis 1 movement amount (10000-1000=9000)

Start point address

(positioning address)

1000

Advertising