23 lend, Melsec-q, Operation – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 414: Positioning data setting examples, Restrictions

Advertising
background image

9 - 114

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.2.23 LEND

The LEND is used to return the operation to the top of the repeat (LOOP to LEND)

loop.

Operation

When the repeat cycle designated by the LOOP becomes 0, the loop is
terminated, and the next positioning data No. processing is started. (The operation
pattern, if set to "Positioning complete", will be ignored.)
When the operation is stopped after the repeat operation is executed by
designated cycles, the dummy positioning data (for example, incremental
positioning without movement amount) is set next to LEND.

Positioning data

No.

Operation pattern

Control system

Conditions

Operation

1

Continuous control

ABS2

2

Positioning

complete

LOOP

Number of loop

cycles: 2

3

Continuous path

control

ABS2

4

Continuous control

ABS2

5

Positioning

complete

LEND

6

Positioning

complete

ABS2

Executed in the

order of the

positioning data

No. 1

2

3

4

5

2

3

4

5

6.

(The operation

patterns of the

positioning data

Nos. 2 and 5 are

ignored.)

Positioning data setting examples

The following table shows the setting examples when "LEND" is set in positioning
data No. 8 of axis 1.

Setting item

Setting example

Setting details

Da.1 Operation pattern

Setting not required. (Setting value is ignored.)

Da.2 Control system

LEND

Set the LEND.

Da.3 Acceleration time No.

Setting not required. (Setting value is ignored.)

Da.4 Deceleration time No.

Setting not required. (Setting value is ignored.)

Da.5

Axis to be
interpolated

Setting not required. (Setting value is ignored.)

Da.6

Positioning address/
movement amount

Setting not required. (Setting value is ignored.)

Da.7 Arc address

Setting not required. (Setting value is ignored.)

Da.8 Command speed

Setting not required. (Setting value is ignored.)

Da.9 Dwell time

Setting not required. (Setting value is ignored.)

A

x

is 1 Positioning data N

o

. 8

Da.10 M code

Setting not required. (Setting value is ignored.)

Refer to Section 5.3 "List of positioning data" for information on the setting details.

Restrictions

(1) Ignore the "LEND" before the "LOOP" is executed.

Advertising