11 MANUAL CONTROL

11.3.4 Creating a program to enable/disable the inching operation

A sequence program must be created to execute an inching operation. Consider the
"required control data setting", "start conditions", and "start time chart" when creating
the program.
The following shows an example when an inching operation is started for axis 1. (The

example shows the inching operation when a "10.0 µm" is set in "

Cd.16

Inching

movement amount".)

Required control data setting

The control data shown below must be set to execute an inching operation. The
setting is carried out with the sequence program.

Buffer memory address

Setting item

Setting

value

Setting details

Axis

1

Axis

2

Axis

3

Axis

4

Cd.16

Inching movement
amount

100

Set the setting value so that the command
pulse is not increased larger than the maximum
output pulse. (The maximum output pulse is 1
Mpps for QD75D

: differential drive output

system), or 200 kpps for QD75P

: open

collector output system.)

1517 1617 1717 1817

Refer to Section 5.7 "List of control data" for information on setting details.

Start conditions

The following conditions must be fulfilled when starting. The required conditions
must also be assembled in the sequence program, and the sequence program
must be configured so the operation will not start if the conditions are not fulfilled.

Device

Signal name

Signal state

Axis

1

Axis

2

Axis

3

Axis

4

PLC READY signal

ON PLC CPU preparation completed

Y0

QD75 READY signal

ON QD75 preparation completed

X0

Synchronization flag

ON

Accessible to QD75 buffer
memory

X1

Axis stop signal

OFF Axis stop signal is OFF

Y4

Y5

Y6

Y7

Start complete signal

OFF Start complete signal is OFF

X10 X11 X12 X13

BUSY signal

OFF QD75 is not operating

XC

XD

XE

XF

Positioning complete
signal

OFF

Positioning complete signal is
OFF

X14 X15 X16 X17

Error detection signal

OFF There is no error

X8

X9

XA

XB

Interface
signal

M code ON signal

OFF M code ON signal is OFF

X4

X5

X6

X7

Drive unit READY signal

ON Drive unit preparation completed

Stop signal

OFF Stop signal is OFF

Upper limit (FLS)

ON Within limit range

External
signal

Lower limit (RLS)

ON Within limit range

If the PLC CPU is set to the asynchronous mode in the synchronization setting, this must be

inserted in the program for interlocking. If it is set to the synchronous mode, it must not be
inserted in the program for interlocking because it is turned ON when the PLC CPU executes
calculation.