12 - 8

MELSEC-Q

12 CONTROL SUB FUNCTIONS

12.2.2 OP shift function

When a machine OPR is carried out, the OP is normally established using the near-

point dog, stopper, and zero signal. However, by using the OP shift function, the

machine can be moved a designated movement amount from the position where the

zero signal was detected. A mechanically established OP can then be interpreted at

that point.

The OP shift function can be used without relation to "

Pr.43

OPR method".

The details shown below explain about the "OP shift function".

[1] Control details

[2] Setting range for the OP shift amount

[3] Movement speed during OP shift

[4] Precautions during control

[5] Setting the OP shift function

[1] Control details

The following drawing shows the operation of the OP shift function.

Machine OPR start

Pr.53 OP shift amount

Speed selected by the " Pr. 56
Speed designation during OP
shift"

Pr.47 Creep speed

Shift operation carried out after

the deviation counter clear and reset.

Pr. 44 OPR direction

Near-point dog

Pr. 46 OPR speed

Zero signal

Fig. 12.4 OP shift operation