4 functions to limit the control, 1 speed limit function, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 497

Advertising
background image

12 - 21

MELSEC-Q

12 CONTROL SUB FUNCTIONS

12.4 Functions to limit the control

Functions to limit the control include the "speed limit function", "torque limit function",

"software stroke limit", and "hardware stroke limit". Each function is executed by

parameter setting or sequence program creation and writing.

12.4.1 Speed limit function

The speed limit function limits the command speed to a value within the "speed limit

value" setting range when the command speed during control exceeds the "speed limit

value".

The details shown below explain about the "speed limit function".

[1] Relation between the speed limit function and various controls

[2] Precautions during control

[3] Setting the speed limit function

[1] Relation between the speed limit function and various controls

The following table shows the relation of the "speed limit function" and various

controls.

Control type

Speed limit function

Speed limit value

Machine OPR control

OPR
control

Fast OPR control

1-axis linear control

2 to 4-axes linear
interpolation control

1-axis fixed-feed control

2 to 4-axes fixed-feed
control (interpolation)

Position
control

2-axis circular interpolation
control

1 to 4-axes Speed control

Speed-position switching control,

Position-speed switching control

Pr.8

Speed limit

value

Current value changing

Major
positioning
control

Other
control

JUMP instruction, NOP
instruction, LOOP to
LEND

Setting value invalid

JOG operation, Inching operation

Pr.31

JOG speed

limit value

Manual
control

Manual pulse generator operation

Setting is invalid

: Always set

– : Setting not required (Setting value is invalid. Use the initial values or setting values

within a range where no error occurs.)