7 other functions, 1 step function, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 534

Advertising
background image

12 - 58

MELSEC-Q

12 CONTROL SUB FUNCTIONS

12.7 Other functions

Other functions include the "step function", "skip function", "M code output function",

"teaching function", "target position change function", "command in-position function",

"acceleration/deceleration processing function", "pre-reading start function",

"deceleration start flag function" and "stop command processing for deceleration stop

function". Each function is executed by parameter setting or sequence program

creation and writing.

12.7.1 Step function

The "step function" is used to confirm each operation of the positioning control one by

one.

It is used in debugging work for major positioning control, etc.

A positioning operation in which a "step function" is used is called a "step operation".

In step operations, the timing for stopping the control can be set. (This is called the

"step mode".) Control stopped by a step operation can be continued by setting "step

continue" (to continue the control)" or restarted by setting "restart" in the "step start

information".

The details shown below explain about the "step function".

[1] Relation between the step function and various controls

[2] Step mode

[3] Step start information

[4] Using the step operation

[5] Control details

[6] Precautions during control

[7] Step function settings

[1] Relation between the step function and various controls

The following table shows the relation between the "step function" and various

controls.

Control type

Step function

Step applicability

Machine OPR control

OPR control

Fast OPR control

Step operation not possible

1-axis linear control
2 to 4-axes linear interpolation control
1-axis fixed-feed control
2 to 4- axes fixed-feed control
(interpolation)

Position
control

2-axis circular interpolation control

Step operation possible

1 to 4- axes Speed control

Step operation not possible

Speed-position switching control
Position-speed switching control

Current value changing

Step operation possible

Major
positioning
control

Other
control

JUMP instruction, NOP instruction,
LOOP to LEND

Step operation not possible

JOG operation, Inching operation

Manual
control

Manual pulse generator operation

Step operation not possible

: Set when required. : Setting not possible

Advertising