12 - 77

MELSEC-Q

12 CONTROL SUB FUNCTIONS

12.7.5 Target position change function

The "target position change function" is a function to change a target position to a

newly designated target position at any timing during the position control (1-axis linear

control). A command speed can also be changed simultaneously.

The target position and command speed changed are set directly in the buffer

memory, and the target position change is executed by "

Cd.29

Target position

change request flag".

The following shows the details of the "target position change function".

[1] Details of control

[2] Precaution during operation

[3] Method of setting target position change function from PLC CPU

[1] Details of control

The following charts show the details of control of the target position change

function.

(a) When the address after change is positioned away from the start point more than the positioning address:

Target position change request

Positioning address Address after change

(b) When the speed is changed simultaneously with changing the address:

Target position change request

Positiioning address Address after change

Speed before
change

Speed after
change

(c) When the direction of the operation is changed:

Target position change

request

Positioning address

Address after
change

Fig. 12.41 Target position change operation