9 deceleration start flag function, Melsec-q, 1] control details – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 568

Advertising
background image

12 - 92

MELSEC-Q

12 CONTROL SUB FUNCTIONS

12.7.9 Deceleration start flag function

The "deceleration start flag function" turns ON the flag when the constant speed status

or acceleration status switches to the deceleration status during position control whose

operation pattern is "Positioning complete". This function can be used as a signal to

start the operation to be performed by other equipment at each end of position control

or to perform preparatory operation, etc. for the next position control.

For the "deceleration start flag function", the following will be explained.

[1] Control details

[2] Precautions during control

[3] Deceleration start flag function setting method

[4] Checking of deceleration start flag

[1] Control details

When deceleration for a stop is started in the position control whose operation

pattern is "Positioning complete", "1" is stored into "

Md

.48

Deceleration start

flag". When the next operation start is made or the manual pulse generator

operation enable status is gained, "0" is stored. (Refer to Fig. 12.51.)

(1) Start made with positioning data No. specified

Time

Operation pattern: Positioning complete (00)

V

Md.48 Deceleration start flag 0

1

0

Fig. 12.51 Operation of deceleration start flag

Advertising