120

H9 ASD Installation and Operation Manual

BIN Input Point 1 Setting

Program

Frequency

Speed Reference Setpoints

This parameter is used to set the gain and bias of the BIN input terminals when
the BIN terminals are used as the control input while operating in the Speed
Control
mode.

The discrete input terminals of the Terminal Board are used as the BIN
terminals.

BIN Input Speed Control Setup

Perform the following setup to allow the system to receive Speed control input
at the BIN input terminals:

• Program

⇒ Fundamental ⇒ Standard Mode Selection ⇒ Frequency Mode

1

Binary/BCD.

• Program

⇒ Fundamental ⇒ Standard Mode Selection ⇒ Command Mode

Selection

Terminal Block.

• Program

⇒ Terminal ⇒ Input Terminals; select and set the desired

discrete input terminals to Binary Bit(s) 0 – 7 (or 0 – MSB). The binary
input word will control the speed of the motor.

• Program

⇒ Terminal ⇒ Input Terminals; select and set a discrete input

terminal to Binary Data Write. Activation of the Binary Data Write
terminal will transfer the status of the Binary Bit(s) 0 – 7 (or 0 – MSB) to
the control board for speed control.

Speed Control

Perform the following setup to allow the system to perform Speed control from
the BIN input terminals:

• Set BIN Input Point 1 Frequency (

F229

).

• Set the BIN input value (% of 255

D

) (

F228

) that represents BIN Input

Point 1 Frequency.

• Set BIN Input Point 2 Frequency (

F231

).

• Set the BIN input value (% of 255

D

) (

F230

) that represents BIN Input

Point 2 Frequency.

• Provide a Run command (F and/or R).

Note:

255

D

is the decimal equivalent of the 8-bit BIN word with all

input terminals set to one (255 decimal = 11111111 binary).

Once set, as the BIN input signal changes are transferred to the control board,
the output frequency of the ASD will vary in accordance with the above
settings.

This parameter sets BIN Input Point 1 Setting and is entered as 0% to 100%
of the of the range represented by the BIN binary input word 11111111 (255

D

)

or the binary bit(s) 0 – MSB.

Direct Access Number — F228

Parameter Type — Numerical

Factory Default — 0

Changeable During Run — Yes

Minimum — 0

Maximum — 100

Units — %

Frequency Settings

F228

F228